Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Stranded |
Still deciding? Get samples of US$ 2/Meter
Request Sample
|
Suppliers with verified business licenses
Lay Guide Wire Cable Boundary safety cable Loop Wire For Robotic Lawn Mowers
Specification
The conductor has aluminum core and is coated with copper and tin.
As this cable corresponds to the cable that comes with many new robotic mower it is
considered by the manufacturers of the robot mowers to be adequate for handling the
mowers loop signal.
An alternative to this cable is our Premium cable of tin-plated copper.
To secure the cable in the ground use Grimsholm signal cable holder.
Conductor material: Tinned copper clad aluminium
Conductor area:1.423mm2
insulation material: PE
Diameter incl insulation: 2.7 mm
H05VV-F
Conductor Area mm² |
Conductor Construction No./mm² |
Insulation Nom. Thick mm |
Insulation Diam mm |
Jecket Nom. Thick mm |
Jecket Diam mm |
AMP Rating(A) |
2×0.5 | 28/0.15 | 0.5 | 2.0 | 0.60 | 5.2 | 6 |
2×0.75 | 42/0.15 | 0.6 | 2.4 | 0.80 | 6.4 | 10 |
2×1.00 | 57/0.15 | 0.6 | 2.5 | 0.80 | 6.7 | 12 |
2×1.50 | 30/0.253 | 0.7 | 3.1 | 0.80 | 7.7 | 16 |
3G0.5 | 28/0.15 | 0.5 | 2.0 | 0.60 | 5.5 | 6 |
3G0.75 | 42/0.15 | 0.6 | 2.4 | 0.80 | 6.8 | 10 |
3G1.00 | 57/0.15 | 0.6 | 2.5 | 0.80 | 7.2 | 12 |
3G1.50 | 30/0.253 | 0.7 | 3.1 | 0.80 | 8.4 | 16 |
Nominal Cross Section mm² |
Insulation Thicknese mm |
Sheath Thickness mm |
Max. Outer Diameter mm |
Ref. Weight kg/ km |
2×2.5 | 0.8 | 1.2 | 10.9 | 120 |
2×4 | 0.8 | 1.2 | 11.9 | 167 |
2×6 | 0.8 | 1.2 | 13.1 | 220 |
3×2.5 | 0.8 | 1.2 | 11.5 | 154 |
3×4 | 0.8 | 1.2 | 12.4 | 210 |
3×6 | 0.8 | 1.5 | 13.9 | 310 |
4×2.5 | 0.8 | 1.2 | 12.5 | 193 |
4×4 | 0.8 | 1.5 | 13.8 | 315 |
4×6 | 0.8 | 1.5 | 15.9 | 413 |
5×2.5 | 0.8 | 1.5 | 13.6 | 243 |
5×4 | 0.8 | 1.5 | 15.7 | 383 |
5×6 | 0.8 | 1.5 | 17.3 | 505 |
10×2.5 | 0.8 | 1.5 | 19.4 | 440 |
14×2.5 | 0.8 | 1.5 | 21 | 579 |
24×2.5 | 0.8 | 1.7 | 27.6 | 961 |
37×2.5 | 0.8 | 1.7 | 31.5 | 1401 |
52×2.5 | 0.8 | 2.0 | 37.7 | 1973 |
Nominal Cross Section mm² |
NO./ Diameter Of Conductor mm |
Insulation Thicknese mm |
Approx Diameter mm |
2×0.75 | 24/0.20 | 0.60 | 7.50 |
2×1.0 | 32/0.20 | 0.60 | 7.80 |
2×1.5 | 30/0.25 | 0.80 | 9.20 |
2×2.5 | 49/0.25 | 0.90 | 11.00 |
2×4.0 | 56/0.28 | 1.00 | 12.50 |
2×6.0 | 84/0.28 | 1.00 | 14.20 |
3x0.75 | 24/0.20 | 0.60 | 7.80 |
3×1.0 | 32/0.20 | 0.60 | 8.00 |
3×1.5 | 30/0.25 | 0.80 | 9.20 |
3×2.5 | 49/0.25 | 0.90 | 11.50 |
3×4.0 | 56/0.30 | 1.00 | 13.30 |
3×6.0 | 84/0.30 | 1.00 | 15.00 |
4×0.75 | 24/0.20 | 0.60 | 8.20 |
4×1.0 | 32/0.20 | 0.60 | 9.20 |
4×1.5 | 30/0.25 | 0.80 | 11.00 |
4×2.5 | 49/0.25 | 0.90 | 12.50 |
4×4.0 | 56/0.30 | 1.00 | 14.80 |
4×6.0 | 84/0.30 | 1.00 | 16.50 |
No. | OD | Conductor | Specification | Material | Color | Wean | Package |
Metal Mesh | 3.8/4.2 | Tinned CCA Tinned Copper |
26×0.25 | HDPE | Green/ Orange/ Black |
AL | 300m/500m/800m/1000m with paperspool |
Double layer | 5.9 | 29×0.25 | AL |
ltem Spec. | AWG Size | NO./ Diameter Of Conductor mm |
Insulation Thicknese mm |
Max. Outer Diameter mm |
Ref. Weight kg/ km |
THW-16B | 16 | 7/0.49 | 0.76 | 2.8 | 19 |
THW-14B | 14 | 7/0.62 | 0.76 | 3.4 | 29 |
THW-12B | 12 | 7/0.78 | 0.76 | 3.9 | 42 |
THW-10B | 10 | 7/0.98 | 0.76 | 4.5 | 62 |
THW-8B | 8 | 7/1.23 | 1.14 | 6 | 103 |
THW-6B | 6 | 7/1.56 | 1.52 | 7.8 | 169 |
THW-4B | 4 | 7/1.96 | 1.52 | 9 | 249 |
THW-3B | 3 | 7/2.20 | 1.52 | 9.7 | 306 |
THW-2B | 2 | 7/2.47 | 1.52 | 10.5 | 376 |
THW-1B | 1 | 19/1.68 | 2.03 | 12.5 | 487 |
THW-1/0B | 1/0 | 19/1.89 | 2.03 | 13.6 | 600 |
THW-2/0B | 2/0 | 19/2.12 | 2.03 | 14.7 | 739 |
THW-3/0B | 3/0 | 19/2.38 | 2.03 | 16 | 912 |
THW-4/0B | 4/0 | 19/2.67 | 2.03 | 17.5 | 1130 |
THW-16A | 16 | 1/1.29 | 0.76 | 2.9 | 19 |
THW-14A | 14 | 1/1.63 | 0.76 | 3.2 | 27 |
THW-12A | 12 | 1/2.05 | 0.76 | 3.6 | 39 |
THW-10A | 10 | 1/2.59 | 0.76 | 4.1 | 59 |
ltem Spec. AWG |
Nominal Cross Section mm² |
NO./ Diameter Of Conductor mm |
Insulation Thicknese mm |
Jacket Thicknese mm |
Max. Outer Diameter mm |
Ref. Weight kg/ km |
20 | 0.519 | 1/0.813 | 0.4 | 0.12 | 2.0 | 7.07 |
18 | 0.823 | 1/1.02 | 0.4 | 0.12 | 2.2 | 10.94 |
16 | 1.31 | 1/1.29 | 0.4 | 0.12 | 2.5 | 16.48 |
14 | 2.08 | 1/1.63 | 0.4 | 0.12 | 2.8 | 23.17 |
16 | 1.31 | 7x0.49 | 0.4 | 0.12 | 2.8 | 17.95 |
14 | 2.08 | 7×0.62/19×0.36 | 0.4 | 0.12 | 3.2 | 23.8 |
12 | 3.31 | 7×0.78/19×0.46 | 0.4 | 0.12 | 3.7 | 35.7 |
10 | 5.26 | 7×0.98/19×0.58 | 0.51 | 0.12 | 4.2 | 56.2 |
8 | 8.37 | 7/1.23/19x0.73 | 0.76 | 0.13 | 5.47 | 93.7 |
6 | 13.3 | 7/1.56/19x0.92 | 0.76 | 0.13 | 6.43 | 141.3 |
4 | 21.15 | 7/1.96/19×1.16 | 1.02 | 0.15 | 8.22 | 227.6 |
2 | 33.62 | 7/2.47/19×1.46 | 1.02 | 0.15 | 9.75 | 348.1 |
1 | 42.36 | 7/2.78/19×1.64 | 1.27 | 0.18 | 11.24 | 446.2 |
1/0 | 53.49 | 19/1.89 | 1.27 | 0.18 | 12.35 | 553 |
2/0 | 67.43 | 19/2.12 | 1.27 | 0.18 | 13.5 | 688.7 |
3/0 | 85.01 | 19/2.39 | 1.27 | 0.18 | 14.85 | 856.8 |
4/0 | 107.2 | 19/2.68 | 1.27 | 0.18 | 16.3 | 1069.5 |
Solar Cable Feature:
|
|
1. 25 years of working Life
|
|
2. Excellent resistance to U.V, oil, greases, oxygen and ozone.
|
|
3. Excellent resistance to abrasion.
|
|
4. Halogen free, flame retardant, low toxicity.
|
|
5. Excellent flexibility and stripping performance.
|
|
6. TUV,EN,IEC approved.
|
FOR FREE: Design new sticker label with your own LOGO
1.we can do the designs according to the customer requirement
2.we can make customized mould according to customer reuirement
3.we can offer you the high quality production & reasionalble price
4.we can offer your a good after-sell service
5.we have strong professinal design team
6. promptly delivery. small order is welcome.
Q1: Are you a factory or trading company?
A1: We are a factory, and guarantee our price is first-hand, cheap and competitive.